IMG_0090-1024x672

Nominal Electrical Output1850 kW
Fuel Operating Range (HHV)
Aspirated configuration:
Direct Inject configuration:

25 – 2600 Btu/scf (0.93 – 97 MJ/m3)
350 – 2600 Btu/scf (13 – 97 MJ/m3)
Nominal Fuel Supply Pressure
Aspirated configuration:
Direct Inject configuration:

5 psig (35 kPa)
140 psig (965 kPa)
Nominal Heat Rate (HHV)9750 Btu/kWh (10,286 kJ/kWh)
NOx Concentration in Exhaust Gas<1 ppm
Electrical Efficiency (LHV)35% (+/- 2)
System Weight105,000 lb (47,627 kg)
System Footprint (Length x Width x Height)50 ft. x 22 ft. x 27 ft.  (15.2m x 6.7m x 8.2m)